Complete, factory-assembled fire water pump house systems from 500 GPM to 5,000+ GPM. NSF/ANSI 61 certified components, NFPA 20 and NFPA 22 compliant, FM Approved and UL Listed — shipped pre-piped, pre-wired, and pre-tested, ready to connect and commission in days, not months.
Every FireGuard™ system ships as a complete, shop-built fire water pump house — pre-piped, pre-wired, factory pressure-tested, and operationally commissioned before it ever leaves our facility. Arrive on-site. Connect utilities. Commission. Done.
FireGuard™ systems carry the full certification stack required by AHJs, insurance underwriters, and engineering specifications. Every certification is product-level — not just process — covering wetted materials, fire pumps, controllers, tanks, and enclosures.
Many jurisdictions now require NSF/ANSI 61 certification for all components in fire suppression systems connected to potable water supplies — not just drinking water systems. California, Washington, Vermont, and the EU Drinking Water Directive all mandate or are moving toward NSF 61 for fire protection connections. FireGuard™ ships NSF 61 compliant as standard, not as an upgrade, eliminating re-specification risk on every project.
Every FireGuard™ system includes: complete hydraulic calculations per NFPA 20 Annex B, pump curve data with system curve overlay, P&ID drawings (AutoCAD and PDF), equipment submittals with UL/FM listing sheets, factory test report signed by MTW PE, and an O&M manual. Optional: PE-stamped drawings for permit submission.
FireGuard™ systems are assembled from purpose-specified, life-safety-grade components. No substitutions, no value-engineered alternatives. Every component selected to NFPA 20, FM, and UL requirements and certified to NSF 61 where wetted.
FireGuard™ systems are available in pre-engineered standard configurations from 500 GPM to 2,500 GPM and custom-engineered for demands to 5,000+ GPM. Multi-pump and multi-train configurations scale capacity while maintaining NFPA 20 redundancy requirements.
| System Model | Rated Flow | Rated Pressure | Electric Pump HP | Diesel Pump HP | Storage (Std.) | Enclosure | Deploy Time | Est. CAPEX | Applications |
|---|---|---|---|---|---|---|---|---|---|
| FG-500 | 500 GPM | 100 PSI | 25 HP | 30 HP diesel | 50,000 gal | Skid-mounted | 72 hrs – 3 wks | $180K–$280K | Light commercial · Small industrial |
| FG-750 | 750 GPM | 100 PSI | 40 HP | 50 HP diesel | 75,000 gal | Skid or enclosure | 3–6 wks | $240K–$360K | Mid-size warehouse · Schools |
| FG-1000 | 1,000 GPM | 100 PSI | 60 HP | 75 HP diesel | 100,000 gal | Enclosed pump house | 6–10 wks | $380K–$560K | Large warehouse · Hospital · Campus |
| FG-1500 | 1,500 GPM | 125 PSI | 100 HP | 125 HP diesel | 150,000 gal | Enclosed pump house | 8–12 wks | $520K–$780K | Distribution center · Manufacturing |
| FG-2000 | 2,000 GPM | 125 PSI | 125 HP | 150 HP diesel | 250,000 gal | Enclosed pump house | 8–14 wks | $720K–$1.1M | Refinery · Data center · Airport |
| FG-2500 | 2,500 GPM | 150 PSI | 200 HP | 200 HP diesel | 350,000 gal | Building / modular | 10–16 wks | $950K–$1.5M | Petrochemical · LNG · Large campus |
| FG-5000+ | 5,000+ GPM | 150–300 PSI | Custom multi-pump | Custom multi-diesel | Custom | Site-specific | 16–26 wks | Custom | Offshore · Mining · Industrial complex |
All systems include: electric fire pump + diesel fire pump + jockey pump + UL-listed controllers + NSF 61 piping + instrumentation + factory test report. Storage tank capacity listed is standard; site-specific storage per NFPA 22 hydraulic demand calculation. CAPEX excludes site civil, utility connections, and AHJ permit fees.
FireGuard™ systems eliminate field assembly entirely. Every system arrives ready to connect. Site work is limited to three utility connections and anchor bolts. Our commissioning team handles the rest.
FireGuard™ systems serve any application requiring a dedicated fire water supply — from light commercial to petrochemical. NFPA 20 compliance and NSF 61 certification are standard across all configurations.
Complete engineering parameters for FireGuard™ standard configurations. All specifications per NFPA 20, NFPA 22, and applicable UL/FM standards. Site-specific designs may vary — consult MTW engineering for custom configurations.
Standard FireGuard™ systems deploy in 8–16 weeks from purchase order. Emergency trailer-mounted systems available for deployment within 72 hours. Timeline excludes AHJ permit review, which typically runs 4–8 weeks concurrently.